Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for fast and easy mart #103 as of September 08, 2022. <br /> Open violations from May 25, 2022 inspection <br /> Violation #203 - Failure to maintain monitoring records for 36 months and maintenance records for 60 <br /> months. <br /> OBSERVATION Maintenance and monitoring records for the last three years were not found on site. <br /> -The 07/2/2021 secondary containment test results were not found on site during the inspection. <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1 ) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance <br /> records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs <br /> of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br /> inventory readings and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the <br /> last three years on site and submit copies to the EHD. <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation #208 - Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION The designated operator failed to check and note all required items on the visual inspection <br /> reports. The incorrect and missing information included the following from the inspection reports: <br /> -The DO reports of 11/1 /2021 , 9/3/2021 , 8/6/2021 , 5/22/2022, 4/22/22, 3/25/20223 2/25/2022 and 1 /28/2022 did not <br /> include the owner/operator name, signature and date signed. <br /> -The DO reports of 12/31 /2021 , 12/01 /20212 10/03/20213 07/08/2021 and 06/09/2021 did not include the <br /> owner/operator name. <br /> -The DO report of 11/01 /2021 did not include follow up actions in section 5 to compliance issues from section 3 <br /> REGULATION GUIDANCE: During the visual inspection , the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Page 2 of 4 <br />