My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WASHINGTON
>
2526
>
2800 - Aboveground Petroleum Storage Program
>
PR0529691
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/20/2022 3:55:03 PM
Creation date
3/22/2022 7:56:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0529691
PE
2832
FACILITY_ID
FA0010245
FACILITY_NAME
DTE STOCKTON LLC
STREET_NUMBER
2526
Direction
W
STREET_NAME
WASHINGTON
STREET_TYPE
ST
City
STOCKTON
Zip
95203
APN
14503009
CURRENT_STATUS
01
SITE_LOCATION
2526 W WASHINGTON ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Observe transformers for signs of abrasion,damage,or deterioration(e.g.,pitted or severely rusted steel, bowing of <br /> pipe between supports,or other deterioration),and assess if there is any oil leakage. <br /> • Observe hydraulic equipment for signs of abrasion,damage,or deterioration(e.g.,pitted or severely rusted steel, <br /> bowing of pipe between supports,or other deterioration),and assess if there is any oil leakage. <br /> Written monthly inspections records are signed by the appointed inspector and maintained with this SPCC Plan for a <br /> minimum period of three years in accordance with 40 CFR§112.7(e)(8). <br /> 8.3 PERIODIC INTEGRITY TESTING (40 CFR 112.8(C)(6)) <br /> Monitoring of the external condition of the above ground tanks by performing a formalized visual inspection once a <br /> month as described in Section 8.2. The above ground storage tanks at the Facility are shop-fabricated and pose a low <br /> risk of internal corrosion. All tanks are under 5,000 gallons and are exempt from the requirements of integrity testing <br /> under Steel Tank Industry(STI)Standard SP001. The STI Standard SP001-00 requires that: <br /> 1. Records of the Periodic Inspections(i.e.,monthly inspections)are kept for at least the previous year and the current <br /> year. <br /> 2. Records of any"Critical Situation"are kept for the entire life of the tank. <br /> If severe corrosion situation is observed or anticipated,integrity testing shall be performed by a certified inspector as <br /> follows: <br /> 1. Hydrostatic testing of the tank for tightness <br /> 2. Non-destructive(ultrasonic)testing of tank shell thickness. <br /> 3. Visual inspection of- <br /> a. Tanks for presence of water in lowest portions of the tank(bacteria in water can cause corrosion),exterior surface <br /> for signs of deterioration, All pipe connections to tank for evidence of leakage, and Operating vents and <br /> emergency vents. <br /> b. Tank supports for integrity,damage and signs of corrosion and damage. <br /> c. Tank foundation for integrity and damage. <br /> 202204 DTEStockton-SPCC RPT.docx 8-3 <br />