LG 162-2 - 5 - <br /> 25290 . 2 (d ) include , but are not limited to , riser piping and access points on top of <br /> the tank , which provide access to the primary containment of the tank and may <br /> be in contact with vapors of the stored product . <br /> 10 . For USTs installed on or after July 1 , 2003 and prior to July 1 , 2004 , is an <br /> annual line tightness test on pressurized piping required ? <br /> Yes . As for all USTs installed since January 1 , 1984 , the requirement for <br /> " underground pressurized piping . . . (to ) be tightness tested annually" also applies <br /> to USTs installed on or after July 1 , 2003 and prior to July 1 , 2004 . [ H & S Code , <br /> §25290 . 2 (g ) ; H & S Code , § 25291 (f) . ] The annual line tightness testing requirement <br /> may be met by satisfying the criteria specified in CCR , Title 23 , Section 2636 (g ) ( 1 . <br /> 5 ) . <br /> PART II : USTs INSTALLED ON OR AFTER JULY 1 , 2004 . <br /> In addition to the requirements discussed below ( Questions A- D of Part II ) , USTs <br /> installed on or after July 1 , 2004 are subject to all of the installation and monitoring <br /> requirements presented in the responses to Questions 1 . 8 of Part I . For USTs installed <br /> on or after July 1 , 2004 , references to the " July 1 , 2003 " date in Part I should be <br /> substituted with "July 1 , 2004 . " The H & S Code citations relevant to USTs installed on or <br /> after July 1 , 2003 and July 1 , 2004 are provided in the table below . Note that Questions <br /> 9 and 10 of Part I do not apply to USTs installed on or after July 1 , 2004 . <br /> H &S Code Citation for USTs H &S Code Citation <br /> Installed On or After July 1 , 2003 and for USTs Installed <br /> Question Prior to July 1 , 2004 On or After July 1 , 2004 <br /> Number ( Part 1 ) ( Part II <br /> 1 H & S Code § 25290 . 2 ( a ) H & S Code 25290 . 1 a <br /> 2 — — <br /> 3 H & S Code § 25290 . 2 (c) (3) H &S Code § 25290 . 1 (c) ( 3 <br /> 4 H & S Code § 25290 . 20 ) H &S Code § 25290 . 1 ( k) <br /> 5 H &S Code § 25290 . 20 ) H & S Code 25290 . 1 k <br /> 6 H &S Code § 25290 . 2 ( i ) H & S Code 25290 . 1 <br /> 7 H &S Code 25290 . 2 H &S Code 25290 . 1 <br /> 8 H &S Code § 25290 . 2 H & S Code § 25290 . 1 <br /> A . In accordance with H &S Code , Section 25290 . 1 ( e ) , which components of <br /> USTs installed on or after July 1 , 2004 must be continuously monitored <br /> using vacuum , pressure , or interstitial liquid level measurement methods ? <br /> The interstitial space of the tank and product piping ( including fill , vent , and vapor <br /> recovery piping ) , that are beneath the surface of the ground must be maintained <br /> under constant vacuum or pressure . Statute also requires that a breach in the <br /> primary or secondary containment be detected before the liquid or vapor of the <br /> stored substance is released to the environment . Continuous vacuum , pressure , <br /> or interstitial liquid level measurement methods can be used to satisfy these <br /> California Envil4onmental Protection Agency <br /> E rZp� Recycled Paper <br />