05110 Structural & Miscellaneous Metals <br /> required. Burned or flame cut edges to be welded shall be chipped clean, and wire <br /> brushed before welding. Clamp members as required, space and alternate welds, all as <br /> may be necessary to prevent warping or misalignment. <br /> 2. Weld Metal: Weld metal shall be thoroughly fused with the base metal along all <br /> surfaces and edges of the union. Penetration shall be 1/16-inch minimum and shall be <br /> into the root of the joint. <br /> 3. Weld Quality: Shall present a uniform surface, free of imperfections, and without <br /> undercutting or overlapping and free from excessive oxides, gas pockets, and non <br /> metallic inclusions. Welds shall be made with the proper number of beads or passes <br /> to secure sound, thoroughly fused joints. Provide backup bars, temporary backup <br /> bars, or backup welds for all full penetration welds. All penetration welds to be full <br /> penetration (U.N.O.). Each deposit shall not exceed AWS Standards for each pass or <br /> bead. Preceding layers shall be by wire brushing or peening to remove scale and slag, <br /> before placing any new weld metal. <br /> 4. Sequence Welding: When welds enclose, or partially enclose, the perimeter or portion <br /> of the surface of a member, the weld bead shall be made in sequence or staggered, so <br /> as to minimize internal stresses. <br /> 5. Faulty and Defective Welding: Any welding showing cracks, slag inclusion, lack of <br /> fusion, bad undercut or other defects, ascertained by visual or other means of <br /> inspection shall be repaired per AWS repair procedures and properly replaced at <br /> Contractor's expense. <br /> 6. Minimum Weld Strengths: Details of fabrication not specifically shown shall follow <br /> in type similar details which may be specifically shown and in all cases, shall at least <br /> match the minimum weld sizes recommended by AISC. All bevel and groove welds <br /> shall be full penetration unless size is noted otherwise. <br /> E. All beams shall be cambered as indicated on the drawings. Beams without camber shall <br /> be fabricated for installation with any "natural" crown up. Cantilever beams to be <br /> fabricated with "crown" down. <br /> F. Grinding: The following structural steel and connections shall be ground smooth: <br /> 1. Exposed cut ends of structural and fabricated shapes. <br /> 2. All welds exposed to view. <br /> 3. Mitered and fit-up corners and intersections. <br /> G. Bolt Holes: <br /> 1. Bolt holes to be 1/16-inch oversize round or oversize 1/16-inch by 1/4-inch oversize <br /> slotted when so noted on the Drawings. <br /> 2. Holes in base plates of anchor bolts may be 1/8-inch oversize. <br /> 3. Edge, end distances and spacing shall conform to those shown on the Drawings. <br /> 3.03 PAINTING AND GALVANIZING <br /> A. After inspection and approval of structural steel by Owner's Testing Laboratory, steel <br /> materials are to be primed with one (1) shop coat of paint when materials are to be <br /> exposed to view and finish painted. Steel materials including bolts and washers are to be <br /> Hot Dip galvanized when exposed to weather and not finish painted or as noted on the <br /> Micke Grove Zoo Wash Water and Septic Disposal System 05110-4 <br /> Siegfried Engineering, Inc. <br /> MESA Project LOCA 0701 <br />