My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0015056
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FAIRCHILD
>
6786
>
2600 - Land Use Program
>
PA-2200134
>
SU0015056
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/6/2022 2:52:53 PM
Creation date
7/22/2022 4:24:09 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0015056
PE
2631
FACILITY_NAME
PA-2200134
STREET_NUMBER
6786
Direction
E
STREET_NAME
FAIRCHILD
STREET_TYPE
LN
City
STOCKTON
Zip
95215-
APN
10129003
ENTERED_DATE
7/22/2022 12:00:00 AM
SITE_LOCATION
6786 E FAIRCHILD LN
RECEIVED_DATE
7/20/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Title Section 9-1015.5[g]) <br /> 2. Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that <br /> such light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> h. LANDSCAPING: Landscaping shall be provided and comply with the following: <br /> 1. A minimum 10-foot-wide landscaped strip, respecting the ultimate right-of-way width of E. Fairchild <br /> Road, shall be installed across the frontage of the project site. (Development Title Section 9- <br /> 1020.8) <br /> The existing landscaping meets this requirement. <br /> 2. SIGNS: Sign details shall be consistent with Chapter 9-1710 of the Development Title and be included on <br /> the Site Plan. All portions of any sign shall be set back a minimum of 5 feet from any future right-of-way <br /> line, including any corner cut-off(snipe). (Development Title Section 9-1710.2[g]) <br /> 3. BUILDING CODE REQUIREMENTS: The project is subject to the California Building Code (CBC) and <br /> San Joaquin County Ordinance requirements. The following conditions shall be addressed prior to <br /> submittal of a building permit application to the Building Inspection Division: <br /> a. A building permit for each separate structure or building is required. Submit plans, specifications <br /> and supporting calculations, prepared by a Registered Design Professional (architect or engineer) <br /> for each structure or building, showing compliance with the current California Building, Mechanical, <br /> Plumbing, Electrical, Energy and Fire Codes as may be applicable. Plans for the different buildings <br /> or structures may be combined into a single set of construction documents. <br /> b. A grading permit will be required for this project. Submit plans and grading calculations, including <br /> a statement of the estimated quantities of excavation and fill, prepared by a Registered Design <br /> Professional. The grading plan shall show the existing grade and finished grade in contour intervals <br /> of sufficient clarity to indicate the nature and extent of the work and show in detail that it complies <br /> with the requirements of the code. The plans shall show the existing grade on adjoining properties <br /> insufficient detail to identify how grade changes will conform to the requirements of the code. <br /> c. This project is located expansive clay soils. A soils report pursuant to CBC Section 1803 for <br /> foundations and appendix Section J104 for grading shall be provided or the foundations shall be <br /> designed using CBC minimum soil bearing pressures. All recommendations of the Soils Report <br /> shall be incorporated into the construction drawings. Where the depth of fill used to create the <br /> building pad exceeds 8 inches, a soils report will be required. <br /> d. For each proposed new building, provide the following information on the plans: <br /> 1. Description of proposed use <br /> 2. Existing and proposed occupancy Groups <br /> 3. Type of construction <br /> 4. Sprinklers (Yes or No) <br /> 5. Number of stories <br /> 6. Building height <br /> 7. Allowable floor area <br /> 8. Proposed floor area <br /> 9. Occupant load based on the CBC <br /> 10. Occupant load based on the CPC <br /> PA-2200134—Conditions of Approval 2 <br />