INSTALL_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4850
>
2300 - Underground Storage Tank Program
>
PR0548363
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 2:39:15 PM
Creation date
5/18/2023 8:35:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548363
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0027616
FACILITY_NAME
G & G INC
STREET_NUMBER
4850
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95215
APN
17948012
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
4850 S STATE ROUTE 99 STOCKTON 95215
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LG 162-2 <br />requirements. As with all leak detection equipment used to monitor the UST <br />system, these methods must be third -party certified and should be listed in Local <br />Guidance (LG) Letter 113. LG 113 can be found on our website at: <br />htti)://www.waterboards.ca.gov/ust/leak 1)revention/lg113/index.html <br />It is important to note that regulated piping begins where piping exits/enters the <br />tank and continues to the point where piping extends above the surface of the <br />ground (e.g., at a shear valve). Statute does not provide an exemption for single - <br />walled piping transitions contained in sumps, or single -walled piping transitions in <br />UDCs, or fill piping contained in sumps. The following options may be used to <br />satisfy the requirements for single -walled piping transitions contained in sumps; <br />single -walled piping transitions contained in UDCs; and fill piping contained in <br />sumps: <br />i. The entire piping length, including piping within sumps or UDCs, must be <br />double -walled and continuously monitored using vacuum, pressure, or <br />interstitial liquid level measurement methods; or <br />ii. The interstitial space between the primary (i.e., single -walled transition <br />pipe or fill piping) and secondary containment (i.e., sump, UDC) must be <br />continuously monitored using vacuum or pressure. (Note: Interstitial liquid <br />level measurement would not be appropriate for this option.); or <br />iii. The single -walled transition pipe or fill piping must be contained within a <br />double -walled sump and/or double -walled UDC that either: (1) extends to <br />the surface or (2) has a double -walled product tight lid that is continuously <br />monitored using vacuum, pressure, or interstitial liquid level measurement <br />methods. The secondary containment (of the sump or UDC, including <br />penetration fittings) must be continuously monitored using vacuum, <br />pressure, or interstitial liquid level measurement methods. <br />Pursuant to Section 2637(a)(6) of Title 23, CCR, portions of the UST system <br />which are continuously monitored using vacuum, pressure, or interstitial liquid <br />level measurement methods are exempt from periodic secondary containment <br />testing. Therefore, periodic secondary containment testing is not required for <br />secondary containment of tank and piping that are continuously monitored using <br />vacuum, pressure, or interstitial liquid level measurement methods. Please note <br />that annual certification of the leak detection equipment is still required. <br />B. What components of USTs installed on or after July 1, 2004 are required to <br />be monitored in accordance with H&S Code, Section 25290.1(d)? <br />Section 25290.1 requires that the "underground storage tank system" be <br />designed and constructed with a continuous monitoring system. Tank and <br />product piping monitored using constant vacuum, pressure, or interstitial liquid <br />level measurement methods satisfy this requirement through Section 25290.1(e). <br />However, other parts of the UST system not subject to Section 25290.1(e) must <br />California Environmental Protection Agency <br />Zai Recycled Paper <br />