COMPLIANCE INFO_JTD 9/3/2025
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
COMPLIANCE INFO_JTD 9/3/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2025 11:06:20 AM
Creation date
10/6/2025 9:32:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
JTD 9/3/2025
RECORD_ID
PR0440004
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
6484 N WAVERLY RD LINDEN 95236
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1437
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUIREMENTS ORDER R5-2015-0058-01 -53- <br />SAN JOAQUIN COUNTY DEPARTMENT OF PUBLIC WORKS <br />FOOTHILL SANITARY LANDFILL, INC. <br />FOOTHILL LANDFILL <br />SAN JOAQUIN COUNTY <br /> <br />8. Closed or partially closed landfill unit side slopes shall be no steeper than 3H:1V, <br />and closed top deck areas shall be sloped at three percent or greater. <br />9. The Discharger shall install and maintain an active landfill gas extraction system <br />appropriately sized to remove LFG from the closed landfill unit throughout the <br />postclosure period. Landfill gas shall be extracted from closed landfill units until <br />such time that the landfill gas is no longer a threat to water quality as <br />documented by the Discharger and approved by the Executive Officer. <br /> <br />10. For closure designs including geomembrane and/or GCL, the Discharger shall <br />seal the edges of the final cover by connecting its components to the base <br />liner, as necessary and feasible. <br />11. The Discharger shall test the critical interfaces of the final cover in a laboratory to <br />ensure minimum design shear strengths are achieved and include the results in <br />the final documentation report. <br />12. The Discharger shall ensure that the vegetative/erosion resistant layer receives <br />necessary seed, binder, and nutrients to establish the vegetation proposed in the <br />final closure plan. The Discharger shall install necessary erosion and sediment <br />controls to prevent sediment in runoff from the closed landfill during the period <br />the vegetation is being established. <br />13. The Discharger shall submit an updated Preliminary CPMP for Calaveras SI. <br />See Provision H.9.i. <br />14. The Discharger shall comply with all Standard Closure and Post-Closure <br />Specifications listed in Section G and all Standard Construction Specifications <br />that are applicable to closure in Section F of the SPRRs dated January 2012 <br />which are attached hereto and made part of this Order by reference. <br />F. FINANCIAL ASSURANCE SPECIFICATIONS <br />1. The Discharger shall obtain and maintain assurances of financial responsibility <br />with CalRecycle for closure and post-closure maintenance of LF-2 in at least the <br />amounts in the most recently approved PC/PCMP, as adjusted for inflation <br />annually. A report regarding financial assurances for closure and post-closure <br />maintenance shall be submitted to the Central Valley Water Board by 1 June of <br />each year. This may be the same report that is submitted to CalRecycle for this <br />purpose. If CalRecycle determines that either the amount of coverage or the <br />mechanism is inadequate, then within 90 days of notification, the Discharger shall <br />submit an acceptable mechanism to CalRecycle and the Central Valley Water <br />Board for at least the amount of the approved cost estimate. <br />2. The Discharger shall update the most recently approved PC/PCMP any time <br />there is a change that will increase the amount of the closure and/or post- <br />closure maintenance cost estimate. The updated PCPCMP shall be submitted to <br />the Central Valley Water Board, the Local Enforcement Agency, and