Laserfiche WebLink
2x6 Rafter <br />, /, <br />FILE NAME <br />Composition Shingles <br />on 1 /2" CDX Plywood <br />Simpson LU24 -� <br />Hanger <br />2x4 studs <br />0 16 O.C. <br />ELEVATION A <br />SCALE: 3/8"=1' 9 <br />1 /2" CCX Plywood <br />at all exposures <br />2X6 Barge Rafter <br />2x6 Outrigger <br />® 24" O.C. <br />Solid 2x6 <br />1,-0„ Blocking <br />DETAIL <br />2 <br />SCALE: 1" =1' 9 <br />2x6 F <br />24" C <br />(DF#2 <br />To P.G.&E. <br />service <br />D ETAI L 1 <br />SCALE: 1" =1 ' 9 <br />5' —3,. <br />12'-0" <br />3'-0" 1 30--9" <br />FLOOR PLAN <br />SCALE: 3/8" =1 ' <br />d Blocking <br />/2" CCX Plywood <br />it all exposures (Typ.) <br />2x6 Fascia board <br />V T1-11 Siding <br />5'O" <br />b <br />ao <br />�J <br />5'x8' Area <br />reserved for <br />250 Gallon <br />Deisel Tank <br />14 <br />SOUTH ELEVATION <br />SCALE: 31T =1 ' <br />EQUIPMENT SCHEDULE <br />�1 Deisel—powered Generator Set, 125 KVA. <br />�2 Air Duct to Radiator with Flexible coupler. <br />3� Louver Vent, 3G' x3fi at Radiator, 30" x36 <br />at south wall. <br />O4 Residential Silencer with heat wrap. <br />5� Diesel lines to Generator Day Tank. <br />O Electric Service Panel, 480/277V, 200A, 4W, 3 0. <br />Automatic Transfer Switch with 4" conduit to <br />riser located as per Generator requirements. <br />O8 Subpanel, 120/240V, 100A, 3W, 1 0. <br />OBooster Pump motor controller, NEMA Class 8502, <br />Size 00. <br />10 <br />Pump Control Panel, NEMA Class 8940, Size 4. <br />11 <br />Fire Extinguisher with AB & C rating. <br />Metal Door and Jamb, 3'-0" x 6'-8", 18 Gage <br />12 <br />Steel with fixed pin hinges and a heavy—duty <br />hasp bolted through the door. <br />13 <br />2" Sch. 80 PVC water line for chlorination system. <br />14 <br />Chlorine solution discharge line. <br />15 <br />3/4' Sch. 80 PVC pressure line from tank to pump <br />switch. <br />1 fi <br />3/4" Conduit from tank —mounted air compressor.' <br />17 <br />Flexible exhaust connector. <br />\a <br />18 <br />Exhaust Thimble for roof penetration with rain cap. <br />19 <br />2x6 DF#2 Rafters 24 O.C. Double rafters at <br />exhaust supports. <br />a �' <br />2D <br />Class A Roof: composition shingles on 1 /2" CDX <br />plywood. <br />21 <br />Booster Pump Shelf, 18"x24" at 34" above floor. <br />22 <br />Foundation — see Sheet 10. <br />(NEST ELEVATION <br />SCALE: 3/8" =1 ' <br />Nall —Mount <br />_fight Fixture <br />;Typical) <br />,It PROJECT ENGINEER DATE CHECKED DATE SUBMITTED DATEL APPLR VED DATE P U M P H 0 U S E SHEET TOTAL <br />SCALE AS NOTED VICTOR WATER SYSTEM IMPROVEMENTS No. SHEETS of <br />�¢ so/ COUNTY OF SAN JOAQUN ELEVATIONS Bc DETAILS 9 12 m <br />DRAWER SHEET NO. ACAD <br />C:\WT0R\ PLAN\ P U M P H OU S <br />