My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU4214 - SU4234A
PublicWorks
>
VAULT MAPS
>
Subdivision - SU
>
SU4000 -
>
SU4214 - SU4234A
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2024 11:00:51 AM
Creation date
10/23/2023 10:01:31 AM
Metadata
Fields
Template:
Subdivision - SU
Subdivision
CSA 31 Well Number 3 Nitrate Treatment System Site
Classification
Record Drawings
Supplemental fields
Agent
Flying J
Cross Ref
SU4214 - SU4234A
DocCategory
Improvement Plans
Year
7/2/2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
t -k A 1:5 U AcA r uA n <br />COUNTY APPROVAL <br />REVISION DESCRIPTION--- <br />APPROVED BY DATE <br />SYMBOLS LIST ABBREVIATIONS <br />SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION A AMPERES, AMBER mA MILLIAMPERES <br />AC ALTERNATING CURRENT MIN MINIMUM <br />GROUND HARDWIRE CONNECTION DIAPHRAGM VALVE ACU AIR CONDITIONING UNIT MOA MANUAL -OFF -AUTO <br />X/ SHEET NOTE TAG - - EXISTING ELECTRIC SIGNAL VALVE ACTUATOR ADR AIR DRYER MOT MOTOR OVERTEMP SENSOR <br />AER AERATOR MOV MOTOR OPERATED VALVE <br />ELECTRICAL SIGNAL � P VALVE POSITIONER <br />i - ALARM HANDLER AGR AGITATOR MTU MODULAR TREATMENT UNIT <br />ELECTRIC POWER/CONTROL GLOBE VALVE <br />Al ANALOG INPUT MUX MULTIPLEXER <br />PNEUMATIC SIGNAL <br />[� GATE VALVE AO ANALOG OUTPUT MWR MOTORIZED WEIR <br />Dxx <br />FIELD MOUNTED INSTRUMENT CAPILARY TUBING (FILLED SYSTEM) (NORMALLY OPEN) B BLUE MXR MIXER <br />xxx FACE MOUNTED INSTRUMENT ON HYDRAULIC SIGNAL GATE VALVE BLR BLOWER N NEUTRAL <br />xxx LOCAL PANEL, OPERATOR ACCESSIBLE (NORMALLY CLOSED) <br />SONIC OR ELECTROMAGNETIC SIGNAL C CLOSE, CONTROL NC NORMALLY CLOSED <br />0xaxxx <br />INSTRUMENT MOUNTED IN LOCAL �- LOGIC OR DATA SIGNAL PLUG VALVE CFE CLEARWELL FILTER EFFLUENT NO NORMALLY OPEN <br />PANEL, OPERATOR INACCESSIBLE (NORMALLY OPEN) <br />� MAIN PROCESS LINE CLR CLARIFIER 0 OPEN <br />xxx FACE MOUNTED INSTRUMENT ON SECONDARY PROCESS LINE ► PLUG VALVE <br />xxx FIELD PANEL, OPERATOR ACCESSIBLE (NORMALLY CLOSED) CMP COMPRESSOR OAC OPEN -AUTO -CLOSE <br />0AUXILIARY PROCESS LINE CR CONTROL RELAY OCA OPEN -CLOSE -AUTO <br />xxx INSTRUMENT MOUNTED IN FIELD - DIRECTION OF FLOW KJ BALL VALVE PB PUSHBUTTON <br />PANEL, OPERATOR INACCESSIBLE (NORMALLY OPEN)CTF CENTRIFUGE <br />XX <br />- MANUFACTURER'S PRE -WIRING BALL d DIFFERENTIAL pH HYDROGEN ION CONCENTRATION <br />OPERATION PERFORMED WITH LOGIC ES f® ECLOSED DC DIRECT CURRENT PID PROPORTIONAL - INTEGRAL - DERIVATIVE <br />< >1WG# <br />DOHARDWIRED DEVICES AS> ELECTRIC SUPPLY OR AIR SUPPLY(NORMALLY )\ - REFERENCE ELEMENTARY DWG. # (DDM) DIGITAL DISPLAY MODULE PLC PROGRAMMABLE LOGIC CONTROLLER <br />/ MOTOR �o 1 BALL CHECK VALVE <br />�/ -- D! DIGITAL INPUT PMP PUMP <br />xxx LAMP INDICATION <br />xxx (STATUS OR ALARM) BUTTERFLY VALVE DO DIGITAL OUTPUT PNL PANEL <br />/ \ <br />U �"j CHECK VALVE DPDT DOUBLE POLE DOUBLE THROW POT POTENTIOMETER <br />DRV DRIVE POV PNEUMATIC OPERATED VALVE <br />DI ANNUNCIATOR WINDOW 1 �) �' BLOWER OR FAN <br />SLUICE GATE (E) EXISTING PS PRESSURE SWITCH <br />Fx_x1 <br />(NORMALLY OPEN) <br />x COMMUNICATIONS POINT COMPRESSOR ETM ELAPSED TIME METER PRV PRESSURE RELIEF VALVE <br />(� SLUICE GATE (F) FUTURE PTT PUSH TO TEST <br />XXX PLC/RTU OR COMPUTER FUNCTION. L] (NORMALLY CLOSED) <br />PROGRAMMING ADDRESS TO INCLUDE PREFIX SUBMERSIBLE PUMP FAN FAN PV PROCESS VARIABLE <br />XX "AUB-O-...... PLUS TAG SHOWN ON P&ID'S. SLIDE GATE <br />(NORMALLY OPEN) FC FAIL CLOSED R RED <br />a FE FLOW METER ELEMENT (R) EXISTING TO BE REMOVED OR RELOCATED <br />VERTICAL PUMP SLIDE GATE REF REFERENCE <br />FY INSTRUMENT PANEL MOUNTED WITH <br />COMPUTING, CONVERTING FUNCTION (NORMALLY CLOSED) FLC FLOCCULATOR <br />FLP FAIL LAST POSITION RVSS REDUCED VOLTAGE SOLID STATE <br />VACUUM RELIEF VALVE <br />CONVERT /* E - VOLTAGE H - HYDRAULIC Q ROTORY LOBE OR GEAR PUMP FLT FILTER S SWITCH <br />I - CURRENT 0 - ELECTROMAGNETIC, SONIC �J PRESSURE RELIEF VALVE FO FAIL OPEN (SIM) SIGNAL INPUT MODULE <br />P - PNEUMATIC R - RESISTANCE (ELECT.) FS FLOAT SWITCH SCR SILICON CONTROLLED RECTIFIER <br />A - ANALOG D - DIGITAL METERING PUMP DIAPHRAGM SEAL G GREEN (SOM) SIGNAL OUTPUT MODULE <br />B - BINARY G, GND GROUND SMP TYPICAL <br />COMPUTE SUMMINGAVERAGING �/n PULSATION DAMPENER GNR MACERATOR/GRINDER SP SET POINT <br />I 7ESV SOLENOID VALVE <br />SUBTRACTOR F RATIO I.•I HMI HUMAN MACHINE INTERFACE SS SURGE SUPPRESSOR <br />MULTIPLYING a DIFFERENCE 1 �] AUDIBLE ALARM (BUZZER OR HORN) PRESSURE REDUCING VALVE HP AIR HIGH PRESSURE AIR TDD, TDE TIME DELAY RELAY <br />DIVIDING HIGH SELECTIN� �' ��- QUICK CONNECT W/CHECK HOA HAND -OFF -AUTO TWP TWISTED PAIR <br />DRAIN <br />ROOT LOW SELECTING © D HOG HYDRAULIC OPERATED GATE TWSP TWISTED SHIELDED PAIR <br />EXTRACTION > 1ARV <br />PROPORTIONAL � INTEGRAL El�,, PAGE THAT LINE IS CONTINUED ON I INTERLOCK TYP TYPICAL <br />DERIVITIVE FD] INTERLOCK 0 �-- REDUCER �M MAGNETIC FLOW METER I/O INPUT/OUTPUT UVC ULTRAVIOLET CHANNEL <br />----- BLIND FLANGED END � MIXER ISR INTRINSICALLY SAFE RELAY V VOLTS, VOLTAGE <br />DIGITAL INPUT I ANALOG INPUT — CAPPED ENDPOSITIVE CAVITY PUMP LOS LOCK -OUT STOP VFD VARIABLE FREQUENCY DRIVE <br />DIGITAL OUTPUT ANALOG OUTPUTTANULAR SEAL LP AIR LOW PRESSURE AIR VLV VALVE <br />LPU LINE PROTECTION UNIT W WHITE <br />M MOTOR WP WEATHERPROOF <br />MA MANUAL -AUTO <br />P & I DIAGRAM INSTRUMENT <br />a� <br />3 <br />SUCCEEDING LETTER(S) <br />M <br />CODE <br />0 <br />W <br />LETTER <br />0 <br />0 <br />0**tf0 <br />twr <br />INITIATING <br />MODIFIER <br />PASSIVE <br />FUNCTION <br />J <br />lu <br />FUNCTION <br />J <br />A <br />ANALYSIS <br />ALARM <br />AUTO <br />B <br />4 <br />C <br />CHLORINE <br />CONTROL <br />L� <br />D <br />DENSITY <br />DIFFERENTIAL <br />Ln C1 <br />E <br />Ln <br />3 � <br />d <br />F <br />FLOW <br />RATIO <br />FUEL <br />00 <br />sQ <br />7� c <br />VIEWING DEVICE <br />H <br />U <br />W (h <br />� L <br />I <br />d d <br />INDICATE <br />N <br />J <br />POWER <br />SCAN <br />Wa <br />0- C <br />K <br />TIME <br />TIME RATE OF <br />C <br />_ <br />CONTROL STATION <br />_J <br />E a <br />t -k A 1:5 U AcA r uA n <br />COUNTY APPROVAL <br />REVISION DESCRIPTION--- <br />APPROVED BY DATE <br />SYMBOLS LIST ABBREVIATIONS <br />SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION A AMPERES, AMBER mA MILLIAMPERES <br />AC ALTERNATING CURRENT MIN MINIMUM <br />GROUND HARDWIRE CONNECTION DIAPHRAGM VALVE ACU AIR CONDITIONING UNIT MOA MANUAL -OFF -AUTO <br />X/ SHEET NOTE TAG - - EXISTING ELECTRIC SIGNAL VALVE ACTUATOR ADR AIR DRYER MOT MOTOR OVERTEMP SENSOR <br />AER AERATOR MOV MOTOR OPERATED VALVE <br />ELECTRICAL SIGNAL � P VALVE POSITIONER <br />i - ALARM HANDLER AGR AGITATOR MTU MODULAR TREATMENT UNIT <br />ELECTRIC POWER/CONTROL GLOBE VALVE <br />Al ANALOG INPUT MUX MULTIPLEXER <br />PNEUMATIC SIGNAL <br />[� GATE VALVE AO ANALOG OUTPUT MWR MOTORIZED WEIR <br />Dxx <br />FIELD MOUNTED INSTRUMENT CAPILARY TUBING (FILLED SYSTEM) (NORMALLY OPEN) B BLUE MXR MIXER <br />xxx FACE MOUNTED INSTRUMENT ON HYDRAULIC SIGNAL GATE VALVE BLR BLOWER N NEUTRAL <br />xxx LOCAL PANEL, OPERATOR ACCESSIBLE (NORMALLY CLOSED) <br />SONIC OR ELECTROMAGNETIC SIGNAL C CLOSE, CONTROL NC NORMALLY CLOSED <br />0xaxxx <br />INSTRUMENT MOUNTED IN LOCAL �- LOGIC OR DATA SIGNAL PLUG VALVE CFE CLEARWELL FILTER EFFLUENT NO NORMALLY OPEN <br />PANEL, OPERATOR INACCESSIBLE (NORMALLY OPEN) <br />� MAIN PROCESS LINE CLR CLARIFIER 0 OPEN <br />xxx FACE MOUNTED INSTRUMENT ON SECONDARY PROCESS LINE ► PLUG VALVE <br />xxx FIELD PANEL, OPERATOR ACCESSIBLE (NORMALLY CLOSED) CMP COMPRESSOR OAC OPEN -AUTO -CLOSE <br />0AUXILIARY PROCESS LINE CR CONTROL RELAY OCA OPEN -CLOSE -AUTO <br />xxx INSTRUMENT MOUNTED IN FIELD - DIRECTION OF FLOW KJ BALL VALVE PB PUSHBUTTON <br />PANEL, OPERATOR INACCESSIBLE (NORMALLY OPEN)CTF CENTRIFUGE <br />XX <br />- MANUFACTURER'S PRE -WIRING BALL d DIFFERENTIAL pH HYDROGEN ION CONCENTRATION <br />OPERATION PERFORMED WITH LOGIC ES f® ECLOSED DC DIRECT CURRENT PID PROPORTIONAL - INTEGRAL - DERIVATIVE <br />< >1WG# <br />DOHARDWIRED DEVICES AS> ELECTRIC SUPPLY OR AIR SUPPLY(NORMALLY )\ - REFERENCE ELEMENTARY DWG. # (DDM) DIGITAL DISPLAY MODULE PLC PROGRAMMABLE LOGIC CONTROLLER <br />/ MOTOR �o 1 BALL CHECK VALVE <br />�/ -- D! DIGITAL INPUT PMP PUMP <br />xxx LAMP INDICATION <br />xxx (STATUS OR ALARM) BUTTERFLY VALVE DO DIGITAL OUTPUT PNL PANEL <br />/ \ <br />U �"j CHECK VALVE DPDT DOUBLE POLE DOUBLE THROW POT POTENTIOMETER <br />DRV DRIVE POV PNEUMATIC OPERATED VALVE <br />DI ANNUNCIATOR WINDOW 1 �) �' BLOWER OR FAN <br />SLUICE GATE (E) EXISTING PS PRESSURE SWITCH <br />Fx_x1 <br />(NORMALLY OPEN) <br />x COMMUNICATIONS POINT COMPRESSOR ETM ELAPSED TIME METER PRV PRESSURE RELIEF VALVE <br />(� SLUICE GATE (F) FUTURE PTT PUSH TO TEST <br />XXX PLC/RTU OR COMPUTER FUNCTION. L] (NORMALLY CLOSED) <br />PROGRAMMING ADDRESS TO INCLUDE PREFIX SUBMERSIBLE PUMP FAN FAN PV PROCESS VARIABLE <br />XX "AUB-O-...... PLUS TAG SHOWN ON P&ID'S. SLIDE GATE <br />(NORMALLY OPEN) FC FAIL CLOSED R RED <br />a FE FLOW METER ELEMENT (R) EXISTING TO BE REMOVED OR RELOCATED <br />VERTICAL PUMP SLIDE GATE REF REFERENCE <br />FY INSTRUMENT PANEL MOUNTED WITH <br />COMPUTING, CONVERTING FUNCTION (NORMALLY CLOSED) FLC FLOCCULATOR <br />FLP FAIL LAST POSITION RVSS REDUCED VOLTAGE SOLID STATE <br />VACUUM RELIEF VALVE <br />CONVERT /* E - VOLTAGE H - HYDRAULIC Q ROTORY LOBE OR GEAR PUMP FLT FILTER S SWITCH <br />I - CURRENT 0 - ELECTROMAGNETIC, SONIC �J PRESSURE RELIEF VALVE FO FAIL OPEN (SIM) SIGNAL INPUT MODULE <br />P - PNEUMATIC R - RESISTANCE (ELECT.) FS FLOAT SWITCH SCR SILICON CONTROLLED RECTIFIER <br />A - ANALOG D - DIGITAL METERING PUMP DIAPHRAGM SEAL G GREEN (SOM) SIGNAL OUTPUT MODULE <br />B - BINARY G, GND GROUND SMP TYPICAL <br />COMPUTE SUMMINGAVERAGING �/n PULSATION DAMPENER GNR MACERATOR/GRINDER SP SET POINT <br />I 7ESV SOLENOID VALVE <br />SUBTRACTOR F RATIO I.•I HMI HUMAN MACHINE INTERFACE SS SURGE SUPPRESSOR <br />MULTIPLYING a DIFFERENCE 1 �] AUDIBLE ALARM (BUZZER OR HORN) PRESSURE REDUCING VALVE HP AIR HIGH PRESSURE AIR TDD, TDE TIME DELAY RELAY <br />DIVIDING HIGH SELECTIN� �' ��- QUICK CONNECT W/CHECK HOA HAND -OFF -AUTO TWP TWISTED PAIR <br />DRAIN <br />ROOT LOW SELECTING © D HOG HYDRAULIC OPERATED GATE TWSP TWISTED SHIELDED PAIR <br />EXTRACTION > 1ARV <br />PROPORTIONAL � INTEGRAL El�,, PAGE THAT LINE IS CONTINUED ON I INTERLOCK TYP TYPICAL <br />DERIVITIVE FD] INTERLOCK 0 �-- REDUCER �M MAGNETIC FLOW METER I/O INPUT/OUTPUT UVC ULTRAVIOLET CHANNEL <br />----- BLIND FLANGED END � MIXER ISR INTRINSICALLY SAFE RELAY V VOLTS, VOLTAGE <br />DIGITAL INPUT I ANALOG INPUT — CAPPED ENDPOSITIVE CAVITY PUMP LOS LOCK -OUT STOP VFD VARIABLE FREQUENCY DRIVE <br />DIGITAL OUTPUT ANALOG OUTPUTTANULAR SEAL LP AIR LOW PRESSURE AIR VLV VALVE <br />LPU LINE PROTECTION UNIT W WHITE <br />M MOTOR WP WEATHERPROOF <br />MA MANUAL -AUTO <br />P & I DIAGRAM INSTRUMENT <br />FUNCTIONAL IDENTIFICATION <br />FIRST LETTER(S) <br />SUCCEEDING LETTER(S) <br />CODE <br />LETTER <br />MEASURED OR <br />READOUT OR <br />OUTPUT <br />INITIATING <br />MODIFIER <br />PASSIVE <br />FUNCTION <br />MODIFIER <br />VARIABLE <br />FUNCTION <br />A <br />ANALYSIS <br />ALARM <br />AUTO <br />B <br />BURNER FLAME <br />C <br />CHLORINE <br />CONTROL <br />CLOSE <br />D <br />DENSITY <br />DIFFERENTIAL <br />DIRECTION <br />E <br />VOLTAGE <br />ELEMENT, SENSOR <br />F <br />FLOW <br />RATIO <br />FUEL <br />FAILURE <br />G <br />GAGING <br />VIEWING DEVICE <br />H <br />HAND <br />HIGH/HAND <br />I <br />CURRENT <br />INDICATE <br />J <br />POWER <br />SCAN <br />K <br />TIME <br />TIME RATE OF <br />CONTROL STATION <br />CHANGE <br />L <br />LEVEL <br />PILOT LIGHT <br />LOW/LOCAL <br />M <br />MOISTURE/MOTOR <br />MOMENTARY <br />MOTOR <br />MIDDLE/MANUAL <br />N <br />STATUS <br />0 <br />OPERATOR <br />ORIFICE <br />OPEN/OVERLOAD <br />P <br />PRESSURE <br />POINT <br />Q <br />EVENT <br />TOTALIZE <br />TOTAL <br />R <br />RESET <br />RECORD <br />RUNNING/REMOTE <br />S <br />SPEED <br />SAFETY <br />SWITCH <br />STOP/SPEED <br />T <br />TEMPERATURE <br />TEST <br />TRANSMIT <br />U <br />MULTIVARIABLE <br />MULTIFUNCTION <br />V <br />VIBRATION/VALVE <br />VALVE <br />W <br />FORCE, WEIGHT <br />WELL <br />X <br />TELEMETRY <br />INTERFACE <br />Y <br />COMPUTER <br />COMPUTE/RELAY/ <br />INTERFACE <br />CONVERTER <br />Z <br />POSITION <br />ACTUATE <br />POSITION <br />Con ection,3 Ey <br />No C'hpnges Ey , <br />s' t '�//i 7 eA <br />Any Person Using This Drawing Should Verify <br />Ail information By inspecting The Site Of Work <br />/®�f ESSIpNq <br />WILLIAM P. y <br />CASSI TY C' <br />E-17132 <br />* p. 09/30P07 <br />�s�t FC TR�� <br />RECORD DRAWING <br />These record drawings have been prepared <br />based on information provided by others. <br />The Engineer has not verified the accuracy <br />of such information and shall not be resp— <br />onsible for any errors or omissions which <br />may be incorporated herein as a result. <br />SCALE BAR IS ONE INCH DATE DESIGNED MB <br />JULY 2007 ECO � 0G I C FLYING J INC. FLYING J-LO.DI DRAINING NUMBER SHEET NUMBER <br />NO SCALE IFOnNOT <br />M1ONE HINCH 1 FILE DRAWN BD Engineering 333 WEST CENTER STREET CSA 31 WELL NUMBER 3 NITRATE P&ID SYMBOLS AND ABBREVIATIONS E13 <br />SCALE ACCORDINGLY FLYJ07-007 CHECKED BC Rocklin, California NORTH SALT LAKE, UT 84054 TREATMENT SYSTEM SITE IMPROVEMENTS 7—OP 22 <br />IF <br />I« <br />IE <br />I© <br />
The URL can be used to link to this page
Your browser does not support the video tag.